C00694

C00695

C00696

C00697

C00698

Parameter | Name:

C00694 | L_Compare 4-5: Hysteresis

Data type: INTEGER_16

Index: 23881

d

= 5D49

h

Hysteresis for the comparison operation selected in

C00693

Setting range

(min. value | unit | max. value)

0.00

%

100.00

Subcodes

Lenze setting

Info

C00694/1

0.00 %

L_Compare_4

: Hysteresis

C00694/2

0.00 %

L_Compare_5

: Hysteresis

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00695 | L_Compare 4-5: Window

Data type: INTEGER_16

Index: 23880

d

= 5D48

h

Window for the comparison operation selected in

C00693

Setting range

(min. value | unit | max. value)

0.00

%

100.00

Subcodes

Lenze setting

Info

C00695/1

0.00 %

L_Compare_4

: Window

C00695/2

0.00 %

L_Compare_5

: Window

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00696 | L_OffsetGainP_1: Offset

Data type: INTEGER_16

Index: 23879

d

= 5D47

h

The

L_OffsetGainP_1

FB: Offset (additive to the input signal)

Setting range

(min. value | unit | max. value)

Lenze setting

-199.99

%

199.99 0.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00697 | L_OffsetGainP_2: Offset

Data type: INTEGER_16

Index: 23878

d

= 5D46

h

The

L_OffsetGainP_2

FB: Offset (additive to the input signal)

Setting range

(min. value | unit | max. value)

Lenze setting

-199.99

%

199.99 0.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00698 | L_OffsetGainP_3: Offset

Data type: INTEGER_16

Index: 23877

d

= 5D45

h

The

L_OffsetGainP_3

FB: Offset (additive to the input signal)

Setting range

(min. value | unit | max. value)

Lenze setting

-199.99

%

199.99 0.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100