2 digital output terminals, Digital output terminals, 7i/o terminals – Lenze 8400 TopLine User Manual

Page 398

Advertising
background image

7

I/O terminals

7.2

Digital output terminals

398

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.2

Digital output terminals

The controller has

• three parameterisable output terminals (DO1 ... DO3) for outputting digital signals
• a relay output (terminal strip X101),
• a (high-current) output for controlling a brake (terminal strip X107).

Parameterisation dialog in the »Engineer«:

Note!

Initialisation behaviour:

• After mains switching up to the start of the application, the digital outputs remain set

to FALSE.

Exception handling:

• In case of a critical exception in the application (e.g. reset), the digital outputs are set

to FALSE considering the terminal polarity parameterised in

C00118

.

Switching cycle diagnostics of the relay:

• A reference for evaluating the wear limit can be obtained via the number of switching

cycles of the relay displayed in

C00177/2

.

Button

Function
Indicates that the polarity of the output is HIGH active.

The polarity can be changed from HIGH active to LOW active by clicking this button.

Indicates that the polarity of the output is LOW active.

The polarity can be changed from LOW active to HIGH active by clicking this button.

Advertising