19

Function library

19.1

Function blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

19.1.158.1 Connection to the basic drive functions (MCK)

Required connections in the FB Editor
'The recommended starting basis for a connection with the FB L_Sequencer_1 is the use of the

TA

"Table positioning"

.

The following configuration shows the required connections in order that the execution of the

prevailing basic function is triggered in

LS_MotionControlKernel

for the two action types

"Positioning" and "Referencing".
With a corresponding parameter setting, the nSet_a output serves to transfer a speed setpoint to

the basic function "speed follower" if an action of Standby" type is active.
The process is reset in the MCK "Standby" operating mode. The internal "StandBy" operating mode

is assumed implicitly if controller inhibit, pulse inhibit, quick stop and/or DC-injection braking are

activated.

"StandBy" operating mode

( 567)

[19-70] Basic integration of the sequence control into the application

Note!

The FB L_Sequencer_1 has to be called in the processing order before the