C01110 | ls_multiencoder: solid measure, C01111 | ls_multiencoder: encoder constant, C01112 | ls_multiencoder: position values – Lenze 8400 TopLine User Manual

Page 1164: C01112/1, C01110, C01111/1, C01111/3, Which is, C01112/2, C01112/3

Advertising
background image

17

Parameter reference

17.2

Parameter list | C01110

1164

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01110

C01111

C01112

Parameter | Name:

C01110 | LS_MultiEncoder: Solid measure

Data type: UNSIGNED_8

Index: 23465

d

= 5BA9

h

From version 02.00.00

Configuration examples can be found in the following chapters:

SinCos absolute value encoder with HIPERFACE® protocol

SSI absolute value encoder with Stegmann-SSI protocol

Selection list

(Lenze setting printed in bold)

Info

0 rotatively unipolar
1 linearly unipolar
2 rotatively bipolar
3 linearly bipolar
4 Inverted rotatively in unipolar mode

From version 15.00.00

5 Inverted linearly in unipolar mode
6 Inverted rotatively in bipolar mode

From version 15.00.00

7 Inverted linearly in bipolar mode

From version 15.00.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01111 | LS_MultiEncoder: Encoder constant

Data type: INTEGER_32

Index: 23464

d

= 5BA8

h

From version 02.00.00

Configuration examples can be found in the following chapters:

SinCos absolute value encoder with HIPERFACE® protocol

SSI absolute value encoder with Stegmann-SSI protocol

Setting range

(min. value | unit | max. value)

1

2147483647

Subcodes

Lenze setting

Info

C01111/1

1

LS_MultiEncoder

: Difference - traverse path

C01111/2

1

LS_MultiEncoder

: Difference - encoder value

C01111/3

1

LS_MultiEncoder

: Traverse path - encoder increment

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01112 | LS_MultiEncoder: Position values

Data type: INTEGER_32

Index: 23463

d

= 5BA7

h

Encoder/feedback system: Multi-Encoder

Setting range

(min. value | unit | max. value)

-214748.3647

units

214748.3647

Subcodes

Lenze setting

Info

C01112/1

0.0000 units

LS_MultiEncoder

: Position offset

C01112/2

-214748.3647 units

LS_MultiEncoder

: Data area min

C01112/3

214748.3647 units

LS_MultiEncoder

: Data area max

C01112/4

0.0000 units

LS_MultiEncoder

: Max. position jump

From version 14.00.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10000