C01067 | inversion of gearbox stages, C01068 | l_switchpoint_1: invert, C01067/1 – Lenze 8400 TopLine User Manual

Page 1152: 17 parameter reference

Advertising
background image

17

Parameter reference

17.2

Parameter list | C01067

1152

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01067

C01068

Parameter | Name:

C01067 | Inversion of gearbox stages

Data type: UNSIGNED_8

Index: 23508

d

= 5BD4

h

From version 02.00.00

Selection list

0 not inverted
1 inverted
2 Automatically from MCK

Subcodes

Lenze setting

Info

C01067/1

0: Not inverted

L_PhiIntegrator_1

: Invert. gearbox nSet_v

C01067/2

0: Not inverted

L_DFSET_1

: Invert. gearbox nSet_v

C01067/3

0: Not inverted

L_CalcDiameter_1

: Invert. gearbox nMotorSpeedAct_v

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01068 | L_SwitchPoint_1: Invert

Data type: UNSIGNED_16

Index: 23507

d

= 5BD3

h

From version 12.00.00

Setting range

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 Invert Output1

Bit set = inversion active

Bit 1 Invert Output2
Bit 2 Invert Output3
Bit 3 Invert Output4
Bit 4 Invert Output5
Bit 5 Invert Output6
Bit 6 Invert Output7
Bit 7 Invert Output8
Bit 8

Reserved

Bit 9

Reserved

Bit 10

Reserved

Bit 11

Reserved

Bit 12

Reserved

Bit 13

Reserved

Bit 14

Reserved

Bit 15

Reserved

Subcodes

Lenze setting

Info

C01068/1

0x0000

L_SwitchPoint_1

: Inversion of outputs

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT