2 requesting the operating mode, Requesting the operating mode, 9basic drive functions (mck) – Lenze 8400 TopLine User Manual

Page 622

Advertising
background image

9

Basic drive functions (MCK)

9.6

Homing

622

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.6.1.6

Option "Actual MCTRL position received at mains switch-off"

The encoder position can be saved with mains failure protection in the controller. For this purpose,

the bit 0 has to be set in

C02652

.

From version 14.00.00

, the "Actual MCTRL position received at mains switch-off" option can also

be accessed in the »Engineer« via the parameterisation dialog for the basic function Homing

(depending on the set position encoder system).

• If bit 0 is set in

C02652

, the actual position of the motor control is saved in the controller (not in

the memory module) and thus remains known to the drive control after mains switching.

The following overview shows the actual position after mains connection depending on the setting

C02652

/bit 0,

C00490

,

C00422

,

C00925

(if resolver is selected) and the existence of the reference

information:

9.6.2

Requesting the operating mode

Request for the "referencing" operating mode by means of the

MCK control word

:

If the MCKInterface is connected upstream to the Motion Control Kernel and if the operating mode

is requested at the

L_MckCtrlInterface

FB, the wOperationMode and bOperationMode_1...8 process

inputs are available.

C02652

bit 0

Reference

available in

case of mains

switch-off

(Status bit

"

HomePos

Available

")

Actual position and status reference in case of mains switch-on with setting

C00490

= 4

C00490

= 0, 3, 4, 10

C00490

= 3

C00422

= 0, 1

C00422

= 2, 3, 4

C00925

= 1

C00925

> 1 (with resolver)

• Resolver

with number of pole

pairs = 1

• Incremental encoder

(TTL)

• Sin/cos encoder

(Singleturn)

• Resolver

with number of pole

pairs > 1

• No sensor

• Absolute value encoder

(Multiturn)

0

0

0 incr.

0 incr.

dnActPos

(mains switch-off)

±

ϑ

Reference is unknown

Reference is unknown

Reference is unknown

1

0 incr.

0 incr.

dnActPos

(mains switch-off)

±

ϑ

Reference is unknown

Reference is unknown

Reference available

1

0

dnActPos

(mains switch-off)

±

ϑ

dnActPos

(mains switch-off)

dnActPos

(mains switch-off)

±

ϑ

Reference is unknown

Reference is unknown

Reference is unknown

1

dnActPos

(mains switch-off)

±

ϑ

dnActPos

(mains switch-off)

dnActPos

(mains switch-off)

±

ϑ

Reference available

Reference available

Reference available

±

ϑ ≡

A rotation within the max. possible angle of rotation is possible at mains switch-off.

MCK control word

Bit 31

...

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

OpMode_Bit3

OpMode_Bit2

OpMode_Bit1

OpMode_Bit0

X

...

X

0

0

0

1

X = Status not significant

Advertising