C02444

C02580

Parameter | Name:

C02444 | CAB configuration

Data type: UNSIGNED_16

Index: 22131

d

= 5673

h

From version 12.00.00

Bit-coded settings

Data transfer axis bus

Setting range

(min. hex value | max. hex value)

0x0000

0xFFFF

Value is bit-coded:

Info

Bit 0 Edge detection SetFail

0 ≡ input bSetFail_DigOut is level-sensitive.

1 ≡ input bSetFail_DigOut is edge-sensitive.

Bit 1

Reserved

Bit 2

Reserved

Bit 3

Reserved

Bit 4

Reserved

Bit 5

Reserved

Bit 6

Reserved

Bit 7

Reserved

Bit 8

Reserved

Bit 9

Reserved

Bit 10

Reserved

Bit 11

Reserved

Bit 12

Reserved

Bit 13

Reserved

Bit 14 same CobId for all Cas
Bit 15 500 kbps

Subcodes

Lenze setting

Info

C02444/1

0x0000

Axis bus configuration

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Parameter | Name:

C02580 | Holding brake: Operating mode

Data type: UNSIGNED_8

Index: 21995

d

= 55EB

h

Selection of the operating mode for holding brake control

Holding brake control

Selection list

(Lenze setting printed in bold)

Info

0 Brake control off

No holding brake is used. Internal control is switched off.

11 Manually controlled

The holding brake is released and closed via a control bit

in the MCK control word.

12 Autom. controlled

The holding brake is automatically released and closed

via speed setpoint comparisons.

13 Semi-automat. controlled

The holding brake is released and closed via a control bit

in the MCK control word.

• In contrast to the manual operation (mode 11)

• the feedforward control is active in this mode,

preventing a sagging e.g. in case of a hoist.

• the brake in this mode also closes when the

controller is inhibited in order to prevent the axis in

a hoist from falling.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1