Parameter list | C00621

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00621/122

0: Not connected

LS_ParReadWrite_6

: bReadWrite

Read/write request 6: Selection of reading/writing

C00621/123

0: Not connected

LS_WriteParamList

: bExecute

Writing the parameter list: Activate

C00621/124

0: Not connected

LS_WriteParamList

: bSelectWriteValue_1

Writing to parameter list: Selection of value set - 1

C00621/125

0: Not connected

LS_WriteParamList

: bSelectWriteValue_2

Writing to parameter list: Selection of value set - 2

C00621/126

0: Not connected

LS_CANManagement

: bResetNode

Reset CAN node

C00621/127

0: Not connected

LS_CANManagement

: bReInitCAN

Reinitialise CAN interface

C00621/128

0: Not connected

LS_DigitalInput

: bPosIn12_Load

Frequency input DI1/DI2: Load angle integrator with

starting value and reset status signal

C00621/147

0: Not connected

LS_TouchProbe

: bDisableTPDigIn3

TP input DI3: Disable TP function dynamically

C00621/148

0: Not connected

LS_TouchProbe

: bDisableTPDigIn4

TP input DI4: Disable TP function dynamically

C00621/149

0: Not connected

LS_TouchProbe

: bDisableTPDigIn5

TP input DI5: Disable TP function dynamically

C00621/150

0: Not connected

LS_TouchProbe

: bDisableTPDigIn6

TP input DI6: Disable TP function dynamically

C00621/151

0: Not connected

LS_TouchProbe

: bDisableTPDigIn7

TP input DI7: Disable TP function dynamically

C00621/152

0: Not connected

LS_TouchProbe

: bDisableTPDigIn3_Rising

TP input DI3: Disable recognition of rising edges

dynamically

C00621/153

0: Not connected

LS_TouchProbe

: bDisableTPDigIn3_Falling

TP input DI3: Disable recognition of falling edges

dynamically

C00621/154

0: Not connected

LS_TouchProbe

: bDisableTPDigIn4_Rising

TP input DI4: Disable recognition of rising edges

dynamically

C00621/155

0: Not connected

LS_TouchProbe

: bDisableTPDigIn4_Falling

TP input DI4: Disable recognition of falling edges

dynamically

C00621/156

0: Not connected

LS_TouchProbe

: bDisableTPDigIn5_Rising

TP input DI5: Disable recognition of rising edges

dynamically

C00621/157

0: Not connected

LS_TouchProbe

: bDisableTPDigIn5_Falling

TP input DI5: Disable recognition of falling edges

dynamically

C00621/158

0: Not connected

LS_TouchProbe

: bDisableTPDigIn3Window

TP input DI3: Enable acceptance window

C00621/159

0: Not connected

LS_TouchProbe

: bDisableTPDigIn4Window

TP input DI4: Enable acceptance window

C00621/160

0: Not connected

LS_TouchProbe

: bDisableTPDigIn5Window

TP input DI5: Enable acceptance window

C00621/161

0: Not connected

LS_AxisBusIO

: bSetFail

Set IO axis bus into the "error" status / IO data exchange

C00621/162

0: Not connected

LS_AxisBusIO

: bResetFail

IO axis bus: Reset "error" status

Parameter | Name:

C00621 | System connection list: Bool

Data type: UNSIGNED_16

Index: 23954