144 l_phidiv_1, 144 l_phidiv_1 2, L_phidiv_1 – Lenze 8400 TopLine User Manual
Page 1622: 19 function library
19
Function library
19.1
Function blocks
1622
Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
19.1.144
L_PhiDiv_1
This FB divides or multiplies angle signals in power of two format.
• A positive division factor (
) causes a division.
• A negative division factor (
) causes a multiplication.
• The value provided at the dnOut_p output is internally limited to ±2147483647 (±2
31
- 1).
• Division is not remainder considered.
Inputs
Outputs
Parameter
Function
Identifier
Data type
Information/possible settings
dnIn_p
DINT
Input signal
Identifier
Data type
Value/meaning
dnOut_p
DINT
Output signal
• Internal limitation to ±2147483647
Parameter
Possible settings
Info
-31
31 Division factor
• Lenze setting: 0
/B3KL'LYB
GQ,QBS
GQ2XWBS
&
r
dnOut_p
dnIn_p
1
2
C01012/1
------------------------
⋅
=