144 l_phidiv_1, 144 l_phidiv_1 2, L_phidiv_1 – Lenze 8400 TopLine User Manual

Page 1622: 19 function library

Advertising
background image

19

Function library

19.1

Function blocks

1622

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

19.1.144

L_PhiDiv_1

This FB divides or multiplies angle signals in power of two format.

• A positive division factor (

C01012/1

) causes a division.

• A negative division factor (

C01012/1

) causes a multiplication.

• The value provided at the dnOut_p output is internally limited to ±2147483647 (±2

31

- 1).

• Division is not remainder considered.

Inputs

Outputs

Parameter

Function

Identifier

Data type

Information/possible settings

dnIn_p

DINT

Input signal

Identifier

Data type

Value/meaning

dnOut_p

DINT

Output signal

• Internal limitation to ±2147483647

Parameter

Possible settings

Info

C01012/1

-31

31 Division factor

• Lenze setting: 0

/B3KL'LYB

GQ,QBS

GQ2XWBS



&



r

dnOut_p

dnIn_p

1

2

C01012/1

------------------------

=

Advertising