C00690 | l_compare_3: function, C00691 | l_compare_3: hysteresis, C00692 | l_compare_3: window – Lenze 8400 TopLine User Manual

Page 1047: C00693 | l_compare 4-5: function, 17 parameter reference

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1047

17

Parameter reference

17.2

Parameter list | C00690

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00690

C00691

C00692

C00693

Parameter | Name:

C00690 | L_Compare_3: Function

Data type: UNSIGNED_8

Index: 23885

d

= 5D4D

h

The

L_Compare_3

FB: Comparison operation

• If the statement of the selected comparison operation is true, the binary bOut output will be set to TRUE.

Selection list

(Lenze setting printed in bold)

1 In1 = In2
2 In1 > In2
3 In1 < In2
4 |In1| = |In2|
5 |In1| > |In2|
6 |In1| < |In2|

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00691 | L_Compare_3: Hysteresis

Data type: INTEGER_16

Index: 23884

d

= 5D4C

h

FB

L_Compare_3

: Hysteresis for the comparison operation selected in

C00690

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

100.00 0.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00692 | L_Compare_3: Window

Data type: INTEGER_16

Index: 23883

d

= 5D4B

h

FB

L_Compare_3

: window for the comparison operation selected in

C00690

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

%

100.00 0.00 %

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00693 | L_Compare 4-5: Function

Data type: UNSIGNED_8

Index: 23882

d

= 5D4A

h

Comparison operation

• If the statement of the selected comparison operation is true, the binary bOut output will be set to TRUE.

Selection list

1 In1 = In2
2 In1 > In2
3 In1 < In2
4 |In1| = |In2|
5 |In1| > |In2|
6 |In1| < |In2|

Subcodes

Lenze setting

Info

C00693/1

1: In1 = In2

L_Compare_4

: Function

C00693/2

1: In1 = In2

L_Compare_5

: Function

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1