1 function 0: evaluate rising signal edges, 2 function 1: evaluate falling signal edges, 1 function 0: evaluate rising signal edges 9 – Lenze 8400 TopLine User Manual

Page 1689: 2 function 1: evaluate falling signal edges 9, 19 function library

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1689

19

Function library

19.1

Function blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

19.1.173.1 Function 0: Evaluate rising signal edges

[19-78] Switching performance for function selection "0: High edge"

Functional sequence

1. A FALSE-TRUE edge at the bIn input sets the bOut output to TRUE.
2. After the parameterised pulse duration has elapsed, the bOut output is reset to FALSE unless

another FALSE/TRUE edge has been set at the bIn input.

• If an additional FALSE-TRUE edge occurs at the bIn input, the pulse duration starts again from

the beginning, i.e. the bOut output can be retriggered.

19.1.173.2 Function 1: Evaluate falling signal edges

[19-79] Switching performance for function selection "1: Low edge"

Functional sequence

1. A TRUE-FALSE edge at the bIn inputs sets the bOut output to TRUE.
2. After the parameterised pulse duration has elapsed, the bOut output is reset to FALSE unless

another TRUE/FALSE edge has been set at the bIn input.

• If an additional TRUE-FALSE edge occurs at the bIn input, the pulse duration starts again from

the beginning, i.e. the bOut output can be retriggered.

Pulse duration

TRUE

FALSE

bOut

t

TRUE

FALSE

bIn

t

Œ

Œ

Œ

Pulse duration

TRUE

FALSE

bOut

t

TRUE

FALSE

bIn

t

Œ

Œ

Œ

Advertising