C01048 | l_gearcomp_1: num_denom, C01049 | l_calcdiameter_1: status, C01050 | l_calcdiameter_1: diameter recalculation – Lenze 8400 TopLine User Manual

Page 1146: C01051 | l_calcdiameter_1: filter time constant, 17 parameter reference

Advertising
background image

17

Parameter reference

17.2

Parameter list | C01048

1146

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01048

C01049

C01050

C01051

Parameter | Name:

C01048 | L_GearComp_1: Num_Denom

Data type: INTEGER_16

Index: 23527

d

= 5BE7

h

From version 02.00.00

Setting range

(min. value | unit | max. value)

-32767

32767

Subcodes

Lenze setting

Info

C01048/1

1

L_GearComp_1

: Numerator

C01048/2

1

L_GearComp_1

: Denominator

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01049 | L_CalcDiameter_1: Status

Data type: INTEGER_16

Index: 23526

d

= 5BE6

h

From version 02.00.00

Display range

(min. value | unit | max. value)

-10

30

Subcodes

Info

C01049/1

L_CalcDiameter_1

: Status

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01050 | L_CalcDiameter_1: Diameter recalculation

Data type: UNSIGNED_32

Index: 23525

d

= 5BE5

h

From version 02.00.00

Setting range

(min. value | unit | max. value)

0.001

Rev.

1000.000

Subcodes

Lenze setting

Info

C01050/1

1.000 rev.

L_CalcDiameter_1

: Diameter recalculation 0

C01050/2

0.100 rev.

L_CalcDiameter_1

: Diameter recalculation 1

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000

Parameter | Name:

C01051 | L_CalcDiameter_1: Filter time constant

Data type: UNSIGNED_16

Index: 23524

d

= 5BE4

h

From version 02.00.00

Setting range

(min. value | unit | max. value)

0.010

s

3.000

Subcodes

Lenze setting

Info

C01051/1

1.000 s

L_CalcDiameter_1

: Filter time constant

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1000