C00074

C00075

C00076

C00077

Parameter | Name:

C00074 | Reset time Imax/M controller

Data type: UNSIGNED_16

Index: 24501

d

= 5FB5

h

Reset time Ti of certain controllers for different motor control modes
Setting range

(min. value | unit | max. value)

0

ms

9990

Subcodes

Lenze setting

Info

C00074/1

65 ms

VFC

: Ti Imax controller

C00074/2

30 ms

SLVC

: Ti torque controller

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00075 | Vp current controller

Data type: UNSIGNED_16

Index: 24500

d

= 5FB4

h

Gain factor Vp of the current controller for servo control (

SC

) and certain inverter functions (parameter

identification, flying restart circuit)

• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered

automatically.

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

V/A

500.00 7.00 V/A

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00076 | Ti current controller

Data type: UNSIGNED_16

Index: 24499

d

= 5FB3

h

Reset time Ti of the current controller for servo control (

SC

) and certain inverter functions (parameter identification,

flying restart circuit)

• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered

automatically.

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

ms

500.00 10.61 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00077 | SC: Vp field controller

Data type: UNSIGNED_16

Index: 24498

d

= 5FB2

h

Gain factor Vp of the field controller for servo control (

SC

)

• After the motor to be used has been selected from the motor catalogue, the suitable value can be entered

automatically.

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

500.00 12.80

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100