C00603 | resp. to feedback, C00604 | resp. to device overload (ixt), C00604 – Lenze 8400 TopLine User Manual

Page 1021: C00603/1, C00603/2, C00603 2, C00603 1, As a response for, Of an error response in, C00603/4

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1021

17

Parameter reference

17.2

Parameter list | C00603

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00603

C00604

Parameter | Name:

C00603 | Resp. to feedback

Data type: UNSIGNED_8

Index: 23972

d

= 5DA4

h

Response of different monitoring modes for the encoder/feedback system

Encoder/feedback system

Selection list

0 No Reaction
1 Fault
2 Trouble
3 TroubleQuickStop
4 WarningLocked
5 Warning
6 Information

Subcodes

Lenze setting

Info

C00603/1

1: Fault

Resp. to MultiEncoder open circuit

C00603/2

1: Fault

Resp. to resolver open circuit

C00603/3

0: No Reaction

Up to and including version 02.xx.xx:

Resp. to encoder communication error

From version 12.00.00:

Resp. to encoder angular drift monitoring

C00603/4

1: Fault

Up to and including version 02.xx.xx:

Resp. to encoder angular drift monitoring

From version 12.00.00:

Resp. to encoder communication error

C00603/5

6: Information

Resp. to Hiperface status

From version 14.00.00

C00603/6

6: Information

Resp. to invalid Hiperface position

From version 14.00.00

C00603/7

6: Information

Resp. to SinCos inaccuracy

From version 14.00.00

C00603/8

1: Fault

Resp. to Hiperface sin/cos deviation

From version 15.00.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00604 | Resp. to device overload (Ixt)

Data type: UNSIGNED_8

Index: 23971

d

= 5DA3

h

Response if the adjustable device utilisation threshold (

C00123

) is reached.

• The current device utilisation is displayed in

C00064

.

Selection list

(Lenze setting printed in bold)

0 No Reaction
1 Fault
5 Warning

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1