C02582

Parameter | Name:

C02582 | Holding brake: Setting

Data type: UNSIGNED_8

Index: 21993

d

= 55E9

h

Activation of functional holding brake control options

Holding brake control

Setting range

(min. hex value | max. hex value)

Lenze setting

0x00

0xFF 0x40 (decimal: 64)

Value is bit-coded: (= bit set)

Info

Bit 0  bMBrakeReleaseOut invert.

Activation of inverted control

• 1 ≡ Inverted logic of the control signal for the holding

brake control switching element.

Bit 1  Horizontal brake protection

Brake response in case of pulse inhibit

• 1 ≡ In the case of a pulse inhibit, the actual speed

value is monitored which must reach the "Close"

threshold value to cause the holding brake to be

applied.

Note:

• This function is only active if bit 3

(horizontal/winding technology) is set as well. The

function is used in order that, when the controller is

inhibited, the holding brake of a drive with horizontal

traverse path does not wear out during rotation.

• With vertical motion (bit 3 = 0), this function is not

active. Especially with hoists and activated pulse

inhibit of the controller, an immediate application of

the brake is essential for safety-related reasons!

Bit 2  with hoist inv. feedfwd. control

Direction of feedforward control with vertical/hoist

technology:

• 0 ≡ Positive direction

• 1 ≡ Negative direction

Note:

Reversal (Ccw) is then considered.

Bit 3  Horizontal application

Direction of movement of the axis

• 0 ≡ The axis performs vertical movements.

Gravitational acceleration causes movements.

• 1 ≡ The direction of the axis is horizontal or rotary. The

gravitational acceleration does not cause any

movement.

Bit 4  Feedforward control C2581

Selection of the feedforward control value

• 0 ≡ Automatic selection.

• The torque saved at the last stop is used.

• 1 ≡ Manual selection.

bMBrakeStartValue2 = FALSE: The feedforward

control value 1 set in

C02581/4

is used.

bMBrakeStartValue2 = TRUE: The feedforward

control value set in

C02581/5

is used.

Bit 5  Feedback monitoring

Activation of status monitoring

• 1 ≡ The bMBrakeApplied input for status detection of

the brake (via a switching contact at the brake) is

monitored after the waiting time set in

C02589/3

has

expired.

Advertising