C01402 | l_sequencer_1: sequence control: status, C01404 | l_sequencer_1: step for bcancel = true, 17 parameter reference – Lenze 8400 TopLine User Manual

Page 1206

Advertising
background image

17

Parameter reference

17.2

Parameter list | C01402

1206

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C01402

C01403

C01404

Parameter | Name:

C01402 | L_Sequencer_1: Sequence control: Status

Data type: UNSIGNED_16

Index: 23173

d

= 5A85

h

From version 12.00.00

0 - READY: Positioning program ready to start/Program end reached.

1 - RUN: Positioning program running.

2 - PAUSE: Current step interrupted, pause active.

3 - BREAK: Positioning program interrupted.

4 - RESET: Positioning program reset.

L_Sequencer_1 (sequence control)

Display range

(min. value | unit | max. value)

0

4

Subcodes

Info

C01402/1

L_Sequencer_1

: Sequence control: Status

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01403 | L_Sequencer_1: Sequence control: Control word

Data type: UNSIGNED_16

Index: 23172

d

= 5A84

h

From version 12.00.00

Bit-coded code for controlling the sequencer with a PC or master control via the parameter channel. Setting a bit to

"1" activates the corresponding function:

• Bit 0: Start

• Bit 1: Pause

• Bit 2: Break

• Bit 3: Cancel

• Bit 4: Reset

• Bit 5: NextStep

L_Sequencer_1 (sequence control)

Setting range

(min. value | unit | max. value)

0

64

Subcodes

Lenze setting

Info

C01403/1

0

L_Sequencer_1

: Sequence control: Control word

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C01404 | L_Sequencer_1: Step for bCancel = TRUE

Data type: UNSIGNED_16

Index: 23171

d

= 5A83

h

From version 12.00.00

L_Sequencer_1 (sequence control)

Setting range

(min. value | unit | max. value)

0

101

Subcodes

Lenze setting

Info

C01404/1

0

L_Sequencer_1

: Step for bCancel = TRUE

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1