2 dead time compensation, 3 switching hysteresis, 2 dead time compensation 3 – Lenze 8400 TopLine User Manual

Page 1683: 3 switching hysteresis 3, 19 function library

Advertising
background image

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1683

19

Function library

19.1

Function blocks

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

19.1.171.2 Dead time compensation

The delay time of external switching elements can be compensated by setting the corresponding

delay time in

C01062/x

. From this input and the current speed ,the FB calculates a preliminary stop,

i.e. the bOut switching output is set correspondingly earlier.

[19-74] Dead time compensation

19.1.171.3 Switching hysteresis

Setting a hysteresis in

C01063/x

serves to prevent a permanent state change of the bOut switching

output that may be caused by actual position value changes due to a mechanical irregularity at the

axis.

[19-75] Switching hysteresis

Tip!
Please note that a delay time set in

C01062/x

shifts the switching points including the

hysteresis.

Switching performance without dead time compensation

Switching performance with dead time compensation

Switching performance of the external switching element (with dead time)

C01062/1

: Dead time

dnSwitchPoint1_p

dn2ndPoint_Size1_p

bOut1*

bOut1

external component

velocity = nActSpeed_v

t

TRUE

TRUE

"ON"

FALSE

FALSE

"OFF"

Œ

0

1

2

CenterMode = FALSE

C01063/1

: Hysteresis

CenterMode = FALSE

CenterMode = TRUE

bOut1

Œ

bOut1

Œ

Œ

Œ

dnSwitchPoint1_p

dn2ndPoint_Size1_p

dnSwitchPoint1_p

dn2ndPoint_Size1_p

Advertising