Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

841

14

Axis bus

14.2

Data transfer axis bus

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

14.2.4

Parameter setting

Short overview of the relevant parameters:

Parameter

Info

Lenze setting

Value Unit

C01120

Sync signal source

0: Off

C02430/1

Axis bus address

• 0 ≡ Node is disconnected from the axis bus

• 1 ≡ Master

• 2 ... 62 ≡ slave 1 ... slave 61

0

C02430/2

Axis bus no. of nodes

• Number of controllers connected to the axis

bus.

2

C02431/1

Axis bus decel. boot-up

3000 ms

C02431/2

Axis bus decel. BusOffRecovery

1000 ms

C02431/3

Axis bus monitoring time

1000 ms

C02440/1

Axis bus IO function

0: Off

Configuring exception handling of the received data

C02442/1

Decoupling inputs from the axis bus

From version 12.00.00

0x0000

C02443/1...11

Decoupling values

From version 12.00.00

0

Axis bus data error monitoring

C00591/1

Resp. to axis bus data error

From version 12.00.00

1: Fault

Diagnostic parameter

C02435

Axis bus status

• Display whether the node participates in the

axis bus data exchange (PDO active) or is

only switched on passively to the axis bus

(PDO stopped).

-

C02436

Axis bus error status

-

C02437

Axis bus MessageError

Integrated error detection

-

C02438/1

Axis bus Tx_Error

From version 12.00.00

• Error counter for faulty sent telegrams.

-

C02438/2

Axis bus Rx_Error

From version 12.00.00

• Error counter for faulty received telegrams.

-

C02438/3

Axis bus transmitting meter

From version 12.00.00

• Display of the entire number of sent

telegrams

-

C02438/4

Axis bus receiving meter

From version 12.00.00

• Display of the entire number of received

telegrams.

-

Highlighted in grey = display parameter