Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

309

5

Motor control (MCTRL)

5.14

Internal interfaces | System block "LS_MotorInterface"

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

dnMotorPosAct_p

DINT

Current position in [increments]

• If the gearbox factor position encoder (

C01203/1..2

) is equal to "1", the motor

position is output.

• Otherwise, if the gearbox factor position encoder (

C01203/1..2

) is not equal to "1"

and a position encoder has been set in

C00490

, a position referring to the position

encoder is output.

dnMotorDeltaPosAct_p

DINT

Current following error in [increments]

• Following error = Difference between set position and actual position

• If the gearbox factor position encoder (

C01203/1..2

) is equal to "1", the motor

following error is output.

• Otherwise, if the gearbox factor position encoder (

C01203/1..2

) is not equal to "1"

and a position encoder has been set in

C00490

, a following error referring to the

position encoder is output.

bLimSpeedCtrlOut

BOOL

"Speed controller or manipulating variable of the slip regulator inside the limitation"

status signal

TRUE The speed controller output is internally limited

bLimSpeedSetVal

BOOL

"Reduction or increase of the setpoint speed active" status signal

TRUE Reduction or increase of the setpoint speed by the I

max

controller is

active

wMaxMotorSpeed

C00011

| BOOL

Reference speed (

C00011

)

nOutputSpeedCtrl_a

INT

Speed controller output

• Scaling: 16384 ≡ 100 % M

max

(

C00057

)

• In case of the "VFC (+encoder)" motor control, this output is the output of the slip

regulator. In this case, the scaling depends on the reference frequency (display in

C00059

):

C00059

< 650 Hz: 16384 ≡ 327.68 Hz (24000 ≡ 480.00 Hz)

C00059

> 650 Hz: 16384 ≡ 655.36 Hz (12000 ≡ 480.00 Hz)

nSpeedCtrlIAct_a

INT

Current value of speed controller integrator

• Scaling depends on the selected motor control:

• V/f control (VFCplus + encoder):

16384 ≡ 100 % reference speed (

C00011

)

• Servo control (SC) or vector control (SLVC):

16384 ≡ 100 % M

max

(

C00057

)

nEffSpeedSetValue_a

INT

Effective speed setpoint

• Scaling: 16384 ≡ 100 % reference speed (

C00011

)

nMotorSpeedAct_a

C00051

| INT

Actual speed value

• Scaling: 16384 ≡ 100 % reference speed (

C00011

)

nMotorSpeedAct_v

INT

Actual speed value

• Scaling: 65535 ≡ 1 revolution

nMotorFreqAct_a

C00058

| INT

Current field frequency

• Scaling depends on the reference frequency (display in

C00059

):

C00059

< 650 Hz: 16384 ≡ 327.68 Hz (24000 ≡ 480.00 Hz)

C00059

> 650 Hz: 16384 ≡ 655.36 Hz (12000 ≡ 480.00 Hz)

bLimTorqueSetVal

BOOL

"Setpoint torque inside the limitation" status signal

TRUE The setpoint torque is internally limited

wMaxMotorTorque

C00057

Maximum motor torque

wMaxMotorTorque = 10 * M

max

(

C00057

)

nInputTorqueCtrl_a

INT

Input value of the torque control (torque setpoint)

• Scaling: 16384 ≡ 100 % M

max

(

C00057

)

nMotorTorqueAct_a

C00056/2

| INT

Actual torque

• In the "VFC (+encoder)" motor control mode, this value is determined from the

current motor current and only approximately corresponds to the actual torque

value..

• Scaling: 16384 ≡ 100 % M

max

(

C00057

)

Identifier

DIS code | data type

Value/meaning