17

Parameter reference

17.2

Parameter list | C00070

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00070

C00071

C00072

C00073

Parameter | Name:

C00070 | Vp speed controller

Data type: UNSIGNED_16

Index: 24505

d

= 5FB9

h

Amplification factor Vp of the speed controller for different motor control modes
Setting range

(min. value | unit | max. value)

0.00

600.00

Subcodes

Lenze setting

Info

C00070/1

15.00

SLVC

: Vp speed controller

C00070/2

6.00

SC

: Vp speed controller

C00070/3

3.00

SLPSM

: Vp speed controller

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00071 | Ti speed controller

Data type: UNSIGNED_16

Index: 24504

d

= 5FB8

h

Reset time Ti of the speed controller for different motor control modes
Setting range

(min. value | unit | max. value)

0.0

ms

6000.0

Subcodes

Lenze setting

Info

C00071/1

100.0 ms

SLVC

: Ti speed controller

C00071/2

50.0 ms

SC

: Ti speed controller

C00071/3

100.0 ms

SLPSM

: Ti speed controller

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Parameter | Name:

C00072 | SC: Tdn speed controller

Data type: UNSIGNED_16

Index: 24503

d

= 5FB7

h

Differential time constant Tdn of the speed controller for servo control (

SC

) and sensorless control for synchronous

motors (

SLPSM

)

Setting range

(min. value | unit | max. value)

Lenze setting

0.00

ms

3.00 0.00 ms

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00073 | Imax/M controller gain

Data type: UNSIGNED_16

Index: 24502

d

= 5FB6

h

Amplification factor Vp of certain controllers for different motor control modes
Setting range

(min. value | unit | max. value)

0.00

100.00

Subcodes

Lenze setting

Info

C00073/1

0.25

VFC

: Vp Imax controller

• After the motor to be used has been selected from the

motor catalogue, the suitable value can be entered

automatically.

C00073/2

1.25

SLVC

: Vp torque controller

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Advertising