Basic drive functions (MCK)

9.9

Stop

648

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

9.9

Stop

If the "normal stop" operating mode is active, the drive is brought to a standstill with a

parameterisable deceleration ramp.

9.9.1

Parameter setting

Short overview of parameters for "Normal stop" operating mode:

9.9.2

Requesting the operating mode

Request for "Normal stop" operating mode by means of the

MCK control word

:

If the MCKInterface is connected upstream to the Motion Control Kernel and if the operating mode

is requested at the

L_MckCtrlInterface

FB, the wOperationMode and bOperationMode_1...8 process

inputs are available.

Parameter

Info

Lenze setting

Value Unit

C01251/1

Normal stop: Deceleration

720.0000 units/s2

C01252/1

Stop: S-ramp time

0.000 s

MCK control word

Bit 31

...

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

OpMode_Bit3

OpMode_Bit2

OpMode_Bit1

OpMode_Bit0

X

...

X

0

1

0

0

X = Status not significant