Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

1263

17

Parameter reference

17.2

Parameter list | C02314

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C02314

C02315

C02430

Parameter | Name:

C02314 | Reserved

Data type: UNSIGNED_8

Index: 22261

d

= 56F5

h

This code is for device-internal use only and must not be written to by the user!

Parameter | Name:

C02315 | LS_WriteParamList: Manual entry of motor type

Data type: UNSIGNED_8

Index: 22260

d

= 56F4

h

From version 14.00.00 onwards

: Parameter values (1st value ... 4th value) for optional

motor data change-over

Selection list

0 Automatic
1 ASM
2 PSM

Subcodes

Lenze setting

Info

C02315/1

0: Automatic

LS_WriteParamList

: c1001_s1_val1

C02315/2

0: Automatic

LS_WriteParamList

: c1001_s1_val2

C02315/3

0: Automatic

LS_WriteParamList

: c1001_s1_val3

C02315/4

0: Automatic

LS_WriteParamList

: c1001_s1_val4

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C02430 | Axis bus address and no. of nodes

Data type: UNSIGNED_8

Index: 22145

d

= 5681

h

From version 02.00.00

Data transfer axis bus

Setting range

(min. value | unit | max. value)

0

62

Subcodes

Lenze setting

Info

C02430/1

0

Axis bus address

• 0 ≡ Node is disconnected from the axis bus

• 1 ≡ Master

• 2 ... 62 ≡ slave 1 ... slave 61

C02430/2

2

Axis bus no. of nodes

• Number of slaves connected to the axis bus.

• Setting only required for the master.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1