_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Parameterisation dialog in the »Engineer«

From the »Engineer« V2.19

, the following parameterisation dialog is available for parameterising

the encoder/feedback system. For a better overview, the parameterisation dialog contains different

categories which can be expanded/collapsed by a simple click. First, only the "encoder selection"

category is expanded:

Go to the Speed sensor selection list field and select the connected speed sensor.

After the selection, the respective category wit the parameters relevant for the selected

encoder is automatically expanded.

Parameter

Info

Lenze setting

C00495

Speed sensor selection

• Source of feedback signal for speed control.

0: No sensor

C00490

Position encoder selection

• Source of feedback signal for position control.

0: no sensor: nSpeedSetValue_a

Detailed information on the parameters of the other categories can be found in the

corresponding chapter:

Resolver (X7)

( 319)

Multi-Encoder (X8)

( 325)

Frequency HTL encoder (DI1/DI2, DI6/DI7)

( 352)

Pole position identification (PPI)

( 358)

Mounting

( 367)

Monitoring

( 368)

Motor temperature monitoring (KTY)

( 373)