C00091 | motor cosine phi, C00092 | motor magnetising inductance, C00093 | power section identification – Lenze 8400 TopLine User Manual

Page 906: C00095 | motor magnetising current, C00097 | rated motor torque, C00091, C00095, C00092, Ing inductance, Moto

Advertising
background image

17

Parameter reference

17.2

Parameter list | C00091

906

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00091

C00092

C00093

C00095

C00097

Parameter | Name:

C00091 | Motor cosine phi

Data type: UNSIGNED_8

Index: 24484

d

= 5FA4

h

This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor

catalogue, the suitable value can be entered automatically.
Setting range

(min. value | unit | max. value)

Lenze setting

0.40

1.00 0.85

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00092 | Motor magnetising inductance

Data type: UNSIGNED_16

Index: 24483

d

= 5FA3

h

After the motor to be used has been selected from the motor catalogue, the suitable value can be entered

automatically. An automatic detection via the motor parameter identification is possible as well.
Setting range

(min. value | unit | max. value)

Lenze setting

0.0

mH

6500.0 81.0 mH

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 10

Parameter | Name:

C00093 | Power section identification

Data type: UNSIGNED_16

Index: 24482

d

= 5FA2

h

Display of the identification of the detected power section of the controller
Display range

(min. value | unit | max. value)

0

65535

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00095 | Motor magnetising current

Data type: UNSIGNED_16

Index: 24480

d

= 5FA0

h

After the motor to be used has been selected from the motor catalogue, the suitable value can be entered

automatically. An automatic detection via the motor parameter identification is possible as well.
Setting range

(min. value | unit | max. value)

Lenze setting

0.00

A

320.00 8.50 A

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00097 | Rated motor torque

Data type: UNSIGNED_32

Index: 24478

d

= 5F9E

h

Display of the rated motor torque

• The value displayed here is calculated from different parameters, e.g. the maximum current set in

C00022

.

Display range

(min. value | unit | max. value)

0.00

Nm

100000.00

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100