2 torque control with speed limitation, Torque control with speed limitation, 5motor control (mctrl) – Lenze 8400 TopLine User Manual

Page 234

Advertising
background image

5

Motor control (MCTRL)

5.9

Servo control (SC)

234

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.9.2.2

Torque control with speed limitation

When bTorquemodeOn = TRUE, a torque-controlled operation is activated. The setpoint torque

directly follows the default value nTorqueSetValue_a.
Due to its speed limitation, the torque-controlled drive can only rotate within a speed range whose

positive speed is limited by nSpeedHighLimit_a and whose negative speed is limited by

nSpeedLowLimit_a.

From version 13.00.00

, the bLimSpeedTorquemodeOn status signal is used to show that the

speed limitation is active.

• The speed is defined by the process.
• The torque setpoint is calculated directly from nTorqueSetValue_a.

From version 12.00.00 onwards,

the torque limitation is active via nTorqueMotLimit_a and

nTorqueGenLimit_a in this control mode, too, for the torque setpoint to be limited. The

torque limitation can be deactivated in

C2865/1

via bit 0 to obtain the previous function.

Note!

• Absolute speed limitation to speed 0 min

-1

(nSpeedLowLimit_a or

nSpeedHighLimit_a = 0) is only possible

from version 12.00.00

.

• Quick stop (QSP) is used to switch over to

Speed control with torque limitation

.

• From version 13.00.00, the torque setpoint nSpeedSetValue_a is set to 0 by quick

stop (QSP) device-internally and the two torque limit values nTorqueMotLimit_a

and nTorqueGenLimit_a are set to 100 % to stop the drive quickly and safely

anytime. The previous behaviour can be set in C2865/1 via bit 12 and bit 13.

Identifier

DIS code | data type

Information/possible settings

nTorqueSetValue_a

C00830/27

| INT

Torque setpoint / additive torque

• Scaling: 16384 ≡ 100 % M

max

(

C00057

)

nSpeedHighLimit_a

C00830/88

| INT

Upper speed limit for the speed limitation

• During torque-controlled operation only (bTorquemodeOn = TRUE)

• Scaling: 16384 ≡ 100 % rated speed (

C00011

)

nSpeedLowLimit_a

C00830/23

| INT

Lower speed limit for speed limitation

• During torque-controlled operation only (bTorquemodeOn = TRUE)

• Scaling: 16384 ≡ 100 % rated speed (

C00011

)

nTorqueMotLimit_a

C00830/29

| INT

Torque limitation in motor mode

• Scaling: 16384 ≡ 100 % M

max

(

C00057

)

• Setting range: 0 … +199.99 %

• If keypad control is performed: Parameterisable via

C00728/1

.

nTorqueGenLimit_a

C00830/28

| INT

Torque limitation in generator mode

• Scaling: 16384 ≡ 100 % M

max

(

C00057

)

• Setting range: -199.99 ... 0 %

• If keypad control is performed: Parameterisable via

C00728/2

.

Advertising