C00806 | l_mpot_1: use, C00807 | l_nlim_1: max.skipfrq, C00808 | l_nlim_1: min.skipfrq – Lenze 8400 TopLine User Manual

Page 1068: C00806, Ctivation is possible via, Or via, Are or'd, 17 parameter reference

Advertising
background image

17

Parameter reference

17.2

Parameter list | C00806

1068

Lenze · 8400 TopLine · Reference manual · DMS 6.0 EN · 06/2014 · TD05/TD14

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C00806

C00807

C00808

Parameter | Name:

C00806 | L_MPot_1: Use

Data type: UNSIGNED_8

Index: 23769

d

= 5CD9

h

The

L_MPot_1

FB: Use of the motor potentiometer

Selection list

(Lenze setting printed in bold)

Info

0 No

The motor potentiometer is not used.

• The analog value applied to the nIn_a input is looped

through without any changes to the nOut_a output.

1 Yes

The motor potentiometer is used.

• The analog value applied at the nIn_a input is led via

the motor potentiometer and provided at the nOut_a

output.

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 1

Parameter | Name:

C00807 | L_NLim_1: Max.SkipFrq.

Data type: INTEGER_16

Index: 23768

d

= 5CD8

h

FB

L_NLim_1

: Maximum blocking frequencies

Setting range

(min. value | unit | max. value)

0.00

%

199.99

Subcodes

Lenze setting

Info

C00807/1

0.00 %

Maximum blocking frequency for zone 1

C00807/2

0.00 %

Maximum blocking frequency for zone 2

C00807/3

0.00 %

Maximum blocking frequency for zone 3

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100

Parameter | Name:

C00808 | L_NLim_1: Min.SkipFrq.

Data type: INTEGER_16

Index: 23767

d

= 5CD7

h

FB

L_NLim_1

: Minimum skip frequencies

Setting range

(min. value | unit | max. value)

0.00

%

199.99

Subcodes

Lenze setting

Info

C00808/1

0.00 %

Minimum blocking frequency for zone 1

C00808/2

0.00 %

Minimum blocking frequency for zone 2

C00808/3

0.00 %

Minimum blocking frequency for zone 2

Read access  Write access  CINH  PLC STOP  No transfer  COM  MOT

Scaling factor: 100