Yaskawa DR2 Sigma Servo User Manual

Page 100

Advertising
background image

3.2 Setting User Constants According to Host Controller

87

Setting

Meaning

Input Signal

0

Does not use the

contact input

P-CON(1CN-41)

Used to switch between P control and PI

control.

0

contact input

speed control

P-CL(1CN-45)

Used for forward external torque limit input

speed control

function.

N-CL(1CN-46)

Used for reverse external torque limit input

Uses the
contact input

0: OFF, 1: ON

contact input
speed control
function.

P-CON

P-CL N-CL Speed Setting

function.
Note
In the case

of the posi-

Direction

of rotation

0

0

Stop (or pulse reference)

1

of the posi-
tion control
type, the re-

0: Forward

1: Reverse

0

1

Cn-1F, SPEED1

type, the re-
ferrence
pulse inhibit

1: Reverse

1

1

Cn-20, SPEED2

pulse inhibit
function
(INHIBIT)

1

0

Cn-21, SPEED3

(INHIBIT)
cannot be
used.

b) Set three motor speeds in the following user constants.

Cn-1F

SPEED1

1st Speed (Contact

Input Speed Control)

Unit:

r/min

Setting

Range: 0 to

Maximum

Speed

Factory

Setting:

100

For Speed/Torque

Control and Position

Control

Cn-20

SPEED2

2nd Speed (Contact

Input Speed Control)

Unit:

r/min

Setting

Range: 0 to

Maximum

Speed

Factory

Setting:

200

For Speed/Torque

Control and Position

Control

Cn-21

SPEED3

3rd Speed (Contact

Input Speed Control)

Unit:

r/min

Setting

Range: 0 to

Maximum

Speed

Factory

Setting:

300

For Speed/Torque

Control and Position

Control

Use these user constants to set motor speeds
when the contact input speed control function
is used (set bit 2 of memory switch Cn-02).

Speed selection input signals P-CL (1CN-45)
and N-CL (1CN-46), and rotation direction
selection signal P-CON (1CN-41) enable the
motor to run at the preset speeds.

c) Set the soft start time (for speed/torque control only).

Cn-07

SFSACC

Soft Start Time

(Acceleration)

Unit:

ms

Setting

Range: 0

to 10000

Factory

Setting: 0

For Speed/Torque

Control and Position

Control

Cn-23

SFSDEC

Soft Start Time

(Deceleration)

Unit:

ms

Setting

Range: 0

to 10000

Factory

Setting: 0

For Speed/Torque

Control and Position

Control

3

Contact input speed control
(Memory switch Cn-02 bit 2 = 1)

Servopack

Contact

input

Run the

motor at

internally

set speed

Servomotor

Advertising