SERVO SELECTION AND DATA SHEETS

5.3.2 Power Consumption

238

5.3.2 Power Consumption

Servopack

Output Current

(Effective

Power Loss

W

<Total>

Power Loss

Type DR2-

(Effective

Value)

A

Main Circuit

Regenerative

Resistor

Control Circuit

Power Loss

W

Supply Voltage

200V

A3Aj

(30W-0.04HP)

0.42

2.9

15.9

A5Aj

(50W-0.07HP)

0.6

4.2

17.2

01Aj

(100W-0.13HP)

0.87

6.3

19.3

02Aj

(200W-0.27HP)

2.0

14.5

27.5

04Aj

(400W-0.53HP)

2.6

22.2

6

41.2

08Aj

(750W-1.01HP)

4.4

36.1

6

13

55.1

Supply Voltage

100V

A3Bj

(30W-0.04HP)

0.63

2.9

15.9

A5Bj

(50W-0.07HP)

0.90

4.4

17.4

01Bj

(100W-0.13HP)

2.2

12.0

25.0

02Bj

(200W-0.27HP)

2.7

16.2

6

35.2

03Bj

(300W-0.40HP)

3.7

20.1

6

39.1

Note

Power loss of regenerative resistor shows the allowable loss. If this value is exceeded, re-
move the built-in regenerative resistor inside the Servopack and install a resistor externally.
Before installing an external regenerative resistor, contact your Yaskawa representative.