5.5 Selecting Peripheral Devices

339

3)

Select 1CN connector for
reference input.

Connector only

1CN connector

DP9420010

Use circuit

breaker for 5 A

power supply

capacity.

Use circuit

breaker for 9 A

power supply

capacity.

Use circuit

breaker for 16 A

power supply

capacity.

Use circuit

breaker for 5 A

power supply

capacity.

Use circuit

breaker for 8 A

power supply

capacity.

Use circuit

breaker for 15 A

power supply

capacity.

Noise filter

Noise filter

Noise filter

Noise filter

from (c)

Servopack power

supply 200 V/100 V?

200 V

100 V

Servopack capacity?

Servopack capacity?

30 to 200W

400W

750W

30 to 100W

200W

300W

Noise filter

LF−205A

LF−220

LF−205A

LF−210

LF−220

4) Select circuit breaker (MCCB)

and noise filter.

Noise filter

LF−210

(0.04 to 0.27HP)

(0.53HP)

(1.01HP)

(0.04 to 0.13HP)

(0.27HP)

(0.40HP)

5)

Select magnetic contactor and
surge suppressor.

Magnetic

contactor

HI−15E5

D

Use one 30 A magnetic contactor for a single
Σ Series, regardless of capacity.

For multiple servo systems, select the
magnetic contactor according to the total
capacity.

to (d)

5

Advertising
This manual is related to the following products: