Yaskawa DR2 Sigma Servo User Manual

Page 175

Advertising
background image

APPLICATIONS OF Σ-SERIES PRODUCTS

3.8.7 Using DR2 Servopack with High Voltage Line cont.

162

2) Select appropriate power transformer capacity according to the following table.

Supply

Voltage

Servopack Type

Power Supply Capacity Per

DR2 Servopack (kVA)

(see note)

DR2-A3Aj

0.25

DR2-A5Aj

0.3

200 V

DR2-01Aj

0.5

200 V

DR2-02Aj

0.75

DR2-04Aj

1.2

DR2-08Aj

2.2

DR2-A3Bj

0.25

DR2-A5Bj

0.3

100 V

DR2-01Bj

0.5

100 V

DR2-02Bj

0.75

DR2-03Bj

1.4

Note At rated load.

3) When 400V class supply voltage is used:

Three-phase

400 or 440 VAC

Power transformer

200 or 100 VAC

Magnetic contactor for

power ON/OFF

Servopack

1MC

1MC

L1

L2

L

N

3

Advertising