4.2 Using the Functions

183

4.2

Using the Functions

This section describes how to use the basic operations described in section 1 to operate
and adjust the motor.

4.2.1

Operation in Alarm Trace-back Mode

183

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.2.2

Operation Using the Digital Operator

186

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.2.3

Autotuning

188

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.2.4

Reference Offset Automatic Adjustment

195

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.2.5

Speed Reference Offset Manual Adjustment Mode

197

. . . . . . . . . . . . . . . . . . .

4.2.6

Clearing Alarm Trace-back Data

200

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.2.7

Checking Motor Type

201

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.2.8

Checking Software Version

201

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.2.1 Operation in Alarm Trace-back Mode

1) The alarm trace-back mode displays up to ten alarms which occurred previously. By al-

lowing confirmation of what alarm occurred when, it is a useful aid to speed up trouble-
shooting.

Alarm Sequence Number

Alarm Code

The higher the number,

the older the alarm data

See the table of

alarms on page 185.

NOTE

The alarm trace-back data is not cleared on alarm reset or when the Servopack power is
turned OFF. This does not adversely affect operation.
The data is cleared using the special mode: Clear alarm trace-back data.