3 setting the number of encoder pulses – Yaskawa DR2 Sigma Servo User Manual

Page 118

Advertising
background image

3.3 Setting Up the Σ Servopack

105

3.3.3 Setting the Number of Encoder Pulses

1) To ensure that the Σ-series Servo System operates properly, set the type of the encoder

to be used and the number of encoder pulses per revolution in the following user
constants:

Cn-02

Bit 9

Encoder Type Selection

Factory

Setting: 0

For Speed/Torque Control

and Position Control

Set the encoder type according to the servomotor type to be used.

After changing the memory switch setting, turn the power OFF, then ON.

Motor Type

Encoder Type

Preset Value

SGM-jjj31j

SGMP-jjj31j

Incremental encoder

0

SGM-jjjW1j

SGMP-jjjW1j

Absolute encoder

1

Cn-11

PULSNO

Number of

Encoder Pulses

Unit: Pulses

Per Revolution

Setting

Range:

Number of

Encoder

Pulses

Factory

Setting:

2048

For Speed/Torque

Control and

Position Control

Set the number of encoder pulses according to the servomotor type to be used. If this
user constant is set incorrectly, system operation cannot be guaranteed.

After changing the user constant setting, turn the power OFF, then ON.

Motor Type

Number of Encoder Pulses Per Revolution

Preset Value

SGM-jjj31j

SGMP-jjj31j

Incremental encoder: 2048 pulses per revolution

2048

SGM-jjjW1j

SGMP-jjjW1j

Absolute encoder: 1024 pulses per revolution

1024