3.8 Special Wiring

159

9) Absolute Encoder Home Position Error Detection

Cn-02 Bit 1

Absolute Encoder Home

Position Error Detection

Factory

Setting: 0

For Speed/Torque Control

and Position Control

This memory switch is used to specify whether to use home position error detection
(alarm A.80) when an absolute encoder is used.

Setting

Meaning

0

Detects a home position error.

1

Does not detect a home position error.

Normally, set this memory switch to “0.”

This memory switch has no significance when an incremental encoder is used.

3.8.6 Extending an Encoder Cable

1) Both incremental and absolute encoders have a standard encoder cable (maximum 20

meters (65.6 ft.)). If a longer cable is required, prepare an extension cable as described
below. The maximum allowable cable length is 50 meters (164 ft.).

a) 3-meter (19.8 ft.) Cable with Connectors:

• For incremental encoder: DP9320082-1
• For absolute encoder: DP9320084-1

TERMS

Home position error detection

This function detects an encoder count error resulting from noise. It checks the number of
pulses per motor revolution, and outputs a home position error alarm if that number is incor-
rect.
If the absolute encoder detects an error, it inverts phase C and notifies the Servopack of the
error. In this case, this “home position error detection” function also works.