2.4 Conducting a Test Run

47

2.4.5 Minimum User Constants Required and Input Signals

1) This section describes the minimum user constants that must be set to conduct a test run.

For details on how to set each user constant, refer to 4.1.5 Operation in User Constant
Setting Mode
.

a) Servopack in speed/torque control mode

Cn-03

Speed reference gain

Cn-0A

Dividing ratio setting

b) Servopack in torque control mode

Cn-13

Torque reference adjustment gain

Cn-0A

Dividing ratio setting

c) Servopack in position control mode

Cn-02 bits 3, 4 and 5

Reference pulse form selection

Cn-24

Electronic gear ratio (numerator)

Cn-25

Electronic gear ratio (denominator)

After changing the Cn-02 setting, always turn the power OFF, then ON. This makes
the new setting valid.

2) If the specified direction of rotation differs from the actual direction of rotation, the wiring

may be incorrect. In this case, recheck the wiring and correct it accordingly. Then, if the
direction of rotation is to be reversed, set the following user constant:

Cn-02 (bit 0)

Reverse rotation mode

After changing the Cn-02 setting, always turn the power OFF, then ON. This makes the
new setting valid.

3) The following table lists the minimum input signals required to conduct a test run. For de-

tails of each input signal, refer to the relevant page.

Signal Name

Pin

Number

Function

S-ON

(servo ON)

1CN-40

Switching between motor ON and OFF status.The

memory switch can be used to eliminate the need for

external short-circuit wiring (see page 132).

P-OT

(forward

rotation

prohibited)

1CN-42

Overtravel limit switch

The memory switch can be used to eliminate the

N-OT

(revere

rotation

prohibited)

1CN-43

The memory switch can be used to eliminate the

need for external short-circuit wiring (see page 54).