65 → input v-ref 1cn-5, Input sg-v 1cn-6 – Yaskawa DR2 Sigma Servo User Manual

Page 78

Advertising
background image

3.2 Setting User Constants According to Host Controller

65

Input V-REF

1CN-5

Speed Reference Input

For Speed/Torque

Control Only

Input SG-V

1CN-6

Signal Ground for Speed

Reference Input

For Speed/Torque

Control Only

Use these signals when speed control is selected
(memory switch Cn-02 bit B = 0).

For ordinary speed control, always wire the V-
REF and SG-V terminals.
Motor speed is controlled in proportion to the input
voltage between V-REF and SG-V.

• Standard Setting:

Cn-03 = 500:

This setting means that 6 V is equivalent to rated speed (3,000 r/min)

Examples:
+6 V input → 3000 r/min in forward direction
+1 V input → 500 r/min in forward direction

−3 V input → 1500 r/min in reverse direction

User constant Cn-03 can be used to change the voltage input range.

• Example of Input Circuit

(See the figure on the right)

For noise control, always use twisted-pair
cables.
Recommended Variable Resistor for Speed Setting:
Type 25HP-10B manufactured by Sakae Tsushin Kogyo Co., Ltd.

When position control is performed by a host con-
troller such as a programmable controller.

Connect V-REF and SG-V to speed reference
output terminals on the host controller. In this
case, adjust Cn-03 according to output voltage
specifications.

Output +15V 1CN-23

+15V power supply for

speed/torque control

For Speed/Torque

Control Only

Output -15V 1CN-24

-15V power supply for

speed/torque control

For Speed/Torque

Control Only

Power output for speed/torque control.
Max. output current is 30mADC.

3

Reference

speed

Standard

setting

Input voltage (V)

Set the slope in

Cn-03 (VREFGN).

4500

3000

1500

-1500

-3000

-4500

Servopack

Host controller

Servopack

Speed

reference

output

terminals

Feedback

pulse input

terminals

↕P: Represents twisted-pair cables

1CN-5

1CN-6

1CN-33
1CN-34
1CN-35
1CN-36