INSPECTION, MAINTENANCE, AND TROUBLESHOOTING

6.2.1 Troubleshooting Problems with Alarm Display cont.

400

Note

An absolute encoder error (A.80) is given initially if a sum-check error (A.82) is generated
during operation.
The sum-check error (A.82) occurs after turning the SEN signal (or Servopack power supply)
OFF and back ON.
However, the sum-check error (A.82) does occur during operation if the host controller is re-
ceiving the S-phase signal (serial data).

D

Display and Outputs

Digital Operator

Di l

d

Alarm Output

g

p

Display and

Alarm Name

Alarm Code Output

Alarm Output

Alarm Name

ALO1

ALO2

ALO3

p

A.83

Absolute encoder

sum-check error

(only if absolute

encoder is used)

OFF

OFF

OFF

OFF

OFF: Output transistor is OFF
ON: Output transistor is ON

Status When Alarm Occurred

C

At control power ON

Cn-01 Bit 1 = 0

Cn-01 Bit 1 = 1

When SEN signal turned

ON, Cn-01 Bit 1 = 0

A

,

B

A

,

B

During operation

(see note)

A,

B

Cause

Remedy

A

• Battery not connected
• Battery connection defective

Check and correct battery connection.

B

Battery voltage below specified value.

Specified value: 2.8 V.

Install new battery and turn SEN signal (or

Servopack control power) ON.

C

Circuit board (1PWB) defective

Replace Servopack.

Note

No alarm occurs at the Servopack when a battery error (A.83) is generated. The battery error
(A.83) occurs the next time the SEN signal (or Servopack) turns ON.
However, the battery error (A.83) can be read during operation if the host controller is receiv-
ing the S-phase signal (serial data).

6