Yaskawa DR2 Sigma Servo User Manual

Page 352

Advertising
background image

SERVO SELECTION AND DATA SHEETS

5.5.1 Selecting Peripheral Devices cont.

340

from (d)

Surge

Suppressor

CR50500BL

6)

Select regenerative unit.

D

Vertical axis

D

Exceeding 3000 r/min.

D

Load inertia exceeds 30 times
motor inertia (50 to 200 W(0.07 to
0.27 HP), or 20 times motor inertia
(400 W(0.53 HP), 750 W(1.01HP)).

D

Frequent acceleration/deceleration

(once per second, or more).

Not application I to IV

Regenerative unit not

needed

End peripheral device selection

Application I to IV

Investigate regenerative unit capacity

using AC Servomotor sizing software.

Result of investigation

into regenerative unit?

Applicable

No regenerative unit

required.

Add

regenerative unit

or external

regenerative

resistor

Regenerative unit

JUSP−RG08

Type of application?

I

II

III

IV

I to IV

D

This is the surge suppressor for HI-15E5,
shown in the previous page.

*2

*2 Regenerative unit : applicable to 200V 30W to 200W

External regenerative resistor : applicable to 100V 200W, 300W or 200V 400W, 750W

When power supply is 100V, 30W to 100W, review the application using larger capacity Servopack.

5

Advertising