Inspection, maintenance, and troubleshooting – Yaskawa DR2 Sigma Servo User Manual

Page 424

Advertising
background image

INSPECTION, MAINTENANCE, AND TROUBLESHOOTING

6.2.3 Internal Connection Diagram and Instrument Connection Examples cont.

412

• 200VAC: 400W, 750W (0.27 HP, 1.01 HP)

100VAV: 200W, 300W (0.53 HP, 0.40HP)

POWER SUPPLY

SINGLE-PHASE

200 TO 230V

OR

SINGLE-PHASE

100 TO 115V

(50/60Hz)

+10%

-15%

+10%

-15%

NOISE

FILTER

POWER

OFF

POWER

ON 1MC

SURGE

SUPPRESSOR

1MC

(1RY)

OPEN AT

SERVO ALARM

FG

DC/DC
CON-
VERTER

ALARM

INDICATION

PRO-
TECTIVE
DETECTION

IN-RUSH CURRENT
PREVENTIVE
CIRCUIT,
REGENERATIVE
PROCESSING

ISO-

LATOR

PWM
REGENERATIVE
CIRCUIT

CURRENT
CONTROL
CIRCUIT

CURRENT
REFERENCE

CURRENT
CONTROL

SPEED
CONTROL

POSITION
CONTROL

SPEED
CALCU-
LATION

RELAY

CURRENT
DETECTION

DB
CIRCUIT

CURRENT
DETECTOR

CHARGE

1MC

L1

L2

L

N

+5V

-5V

PG5V

CPU

PM1

DB1

U
V

W

RED

WHITE

BLUE

GREEN

PG

2CN

4CN

1CN

3CN

FOR LINE PG SIGNALS

(FULL-CLOSED LOOP

SPECIFICATIONS)

FOR I/O SIGNALS

FOR SETTING DEVICE

AC SERVOMOTOR

Y3

Y4

TR2

6

Advertising
This manual is related to the following products: