Yaskawa DR2 Sigma Servo User Manual

Page 94

Advertising
background image

3.2 Setting User Constants According to Host Controller

81

2) Contact Output Signal Terminal Connections

These output signals are used

to indicate DR2 Servopack

operation status.

Servopack

Photocoupler output
Per output
Maximum operational

voltage: 30 VDC

Maximum output

current: 50 mA DC

Open collector output
Per output
Maximum operational

voltage: 30 VDC

Maximum output

current: 20 mA DC

Photocoupler

Host controller

I/O power

supply

Note Provide an external I/O power supply separately.

There are no power terminals to which the DR2 Servopack outputs signals exter-
nally.
Yaskawa recommends that this external power supply be the same type as for the
input circuit.

Output SG

1CN-2

Signal Ground for Alarm

Code Output Signal

For Speed/Torque

Control and

Position Control

This signal ground is used for the following output signals. Connect to 0 V on the external
power supply.

Contact Output Signals: ALO1

(1CN-37)

ALO2

(1CN-38)

ALO3

(1CN-39)