SERVO SELECTION AND DATA SHEETS

5.6.1 Cable Specifications and Peripheral Devices cont.

354

3) The appropriate cables for Servopack connectors 1CN and 2CN are shown in the table

below. As for the cables conforming to the EMC instructions, refer to 7.2.4 and 7.2.5.

Control I/O Signal

Connector

1CN Cable

Use twisted-pair cable or twisted-pair

shielded cable.

Max. wiring length is 3m (9.8ft.).

Finished Cable

Dimensions

φ16.0 mm (φ 0.63 in.)MAX.

PG Signal Connector 2CN Cable

Use Yaskawa cable.

Use twisted-pair shielded cable if

Yaskawa cable is not used.
If using cable other than Yaskawa’s,

If using cable other than Yaskawa s,

use AWG22 for encoder power supply

and FG line. Use AWG26 for other

signals. These connections permit

wiring distances up to 20 m (65.6 ft).

Finished Cable

Dimensions

φ11.0mm (φ0.43 in.) MAX.

5