APPLICATIONS OF Σ-SERIES PRODUCTS

3.2.6 Using Contact Input Speed Control cont.

90

4) The figure below illustrates an example of operation in contact input speed control mode.

Using the soft start function reduces physical shock at speed changeover.

When Contact Input Speed Control is Used

Motor speed

Stopped

1st speed

2nd speed

3rd speed

Set acceleration and

deceleration values in Cn-07

and Cn-23 (soft start time).

Stopped

1st speed

2nd speed

3rd speed

Stopped

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF

ON

ON

ON

ON

ON

ON

ON

ON

ON

Note

For the position control, the soft start function is available only when contact input
speed control is used. The soft start function is not available when pulse reference
input is used.
For the position control type, if contact input speed control mode is switched to
pulse reference input mode when the motor is running at the 1st, 2nd or 3rd
speed, the Servopack does not receive a pulse reference until positioning com-
plete signal COIN is output.

Always start outputting a pulse reference from the host controller after a position-
ing complete signal is output from the Servopack.

Signal Generation Timing for Position Control Type

Motor speed

0 r/min

Pulse reference

Selected speed

1st speed

2nd speed

3rd speed

Pulse reference

COIN

N-CL

P-CL

1st speed

The above figure illustrates signal generation timing when the soft start function is
used.
The value of t

1

is not influenced by use of the soft start function.

A maximum of 6 ms delay occurs when P-CL or N-CL signal is read.