1) The following diagram shows a typical example of wiring the main circuit for Σ-Series

products:

1MCCB: Circuit breaker

1FIL:

Noise filter

1MC:

Contactor

1Ry:

Relay

1PL:

Patrol light

1SUP:

Surge suppressor

1D:

Flywheel diode

For 100 V Type

Single-phase 100 to 115 VAC

50/60 Hz

Single-phase 200 to 230 VAC

50/60 Hz

+ 10

15 %

,

+ 10

15 %

,

1MCCB

R

T

1FIL

Main Power

OFF

ON

1MC

1Ry

1MC

1SUP

1PL

L1

ALM+

U

V

W

Servopack DR2

1MC

L2

L

N

1Ry

ALM-

A

B

C

D

M

PG

1Ry

31

32

1CN

1D

+24V

0

24

V

2) The following table shows the name and description of each main circuit terminal:

Terminal

Symbol

Name

Description

L1, L2

Main circuit AC

input

Single-phase 200 to 230 VAC

, 50/60Hz*

1

+ 10

15 %

L, N

Control power

supply input

Single-phase 200 to 230 VAC

, 50/60Hz*

1

+ 10

15 %

U, V, W Motor connection

Connects terminal U to motor terminal (red), V to (white)

and W to (blue).

×2

Ground terminal

Connects to ground and motor terminal (for ground and

motor grounding)

Y3, Y4

Regenerative

resistor connection

Regenerative resistor connection (External connection is not

normally required.)*

2

+, −

Regenerative unit

connection

Regenerative unit connection terminal (Connection is not

normally required.)*

3

*1 For 100 V power supply: Single-phase 100 to 115 VAC

+ 10

15 %

, 50/60Hz

*2 Provided only for types 400W, 750W (200VAC) and 200W, 300W (100VAC).
*3 Provided only for types 30W to 200W (200VAC).