3.8 Special Wiring

157

• Use the following user constant to set the pulse dividing ratio.

Cn-0A

PGRAT

Dividing Ratio

Setting

Unit: P/R

Setting Range:

16 to Number

of Encoder

Pulses

Factory

Setting:

2048

For Speed/Torque

Control and

Position Control

Set the number of output pulses for PG output
signals (PAO,

*

PAO, PBO and

*

PBO).

Pulses from motor encoder (PG) are divided
by the preset number of pulses before being
output.

The number of output pulses per revolution is
set in this user constant. Set this value accord-
ing to the reference unit of the machine or con-
troller to be used.

The setting range varies according to the en-
coder used.

Motor Type

Number of Encoder Pulses Per

Revolution

Setting Range

SGM-jjj31j

SGMP-jjj31j

Incremental encoder: 2048 pulses

per revolution

16 to 2048

SGM-jjjW1j

SGMP-jjjW1j

Absolute encoder: 1024 pulses per

revolution

16 to 1024

3

Servomotor

encoder

Servopack

Output terminals:
PAO (1CN-33)

*PAO (1CN-34)

PBO (1CN-35)

*PBO (1CN-36)

Setting example:

Preset value: 16

1 revolution

Phase A

Phase A

Phase B

Phase B

Output

Fre-