94 → input t-ref 1cn-9, Input sg-t 1cn-10, Input v-ref 1cn-5 – Yaskawa DR2 Sigma Servo User Manual

Page 107: Input sg-v 1cn-6

Advertising
background image

APPLICATIONS OF Σ-SERIES PRODUCTS

3.2.7 Using Torque Control cont.

94

Input T-REF 1CN-9

Torque Reference Input

For Speed/Torque

Control Only

Input SG-T 1CN-10

Signal Ground for Torque

Reference Input

For Speed/Torque

Control Only

These signals are used when torque control is se-
lected (bits A and B of memory switch Cn-01).

Motor torque is controlled so that it is proportional
to the input voltage between T-REF and SG-T.

Standard Setting
Cn-13 = 30:

This setting means that 3 V is

equivalent to rated torque.

Examples:

+3 V input → Rated torque in forward direction
+9 V input → 300% of rated torque in forward direction
−0.3 V input → 10% of rated torque in reverse direction

User constant Cn-13 can be used to change the voltage input range.

Example of Input Circuit:
See the figure on the right.

• For noise control, always use twisted-

pair cables.

• Example of Variable Resistor for Speed Setting:

Type 25HP-10B manufactured by Sakae Tsushin Kogyo Co., Ltd.

Input V-REF 1CN-5

Speed Reference Input (or

Speed Limit Input)

For Speed/Torque

Control Only

Input SG-V

1CN-6

Signal Ground for Speed

Reference Input

For Speed/Torque

Control Only

These signals are used when speed control is se-
lected (bits A and B of memory switch Cn-01).

For normal speed control, always connect these
signal terminals.

Motor speed is controlled so that it is proportional
to the input voltage between V-REF and SG-V.

Standard Setting
Cn-03 = 500: This setting means that 6 V is equivalent to rated speed (3000 r/min).

Examples:

+6 V input → 3000 r/min in forward direction
+1 V input → 500 r/min in forward direction
−3 V input → 1500 r/min in reverse direction

3

Reference

torque

(%)

Standard

setting

Input voltage

(V)

Set the

slope in

Cn-13

(TCRFGN).

300

200

100

-100

-200

-300

Servopack

Reference

speed (r/min)

Standard

setting

Input voltage

(V)

Set the slope

in Cn-03

(VREFGN).

4500

3000

1500

-1500

-3000

-4500