APPLICATIONS OF Σ-SERIES PRODUCTS

3.2.5 Using Electronic Gear cont.

84

f) Set the electronic gear ratio in the user constants below.

Reduce the electronic gear ratio

B

A

to their lowest terms so that both A and B are an

integer smaller than 65535, then set A and B in the following user constants.

B

A

Cn-24

RATB Electronic gear ratio (numerator)

Cn-25

RATA Electronic gear ratio (denominator)

This is all that is required to set the electronic gear.

Cn-24

RATB

Electronic Gear Ratio

(Numerator)

Unit:

None

Setting

Range: 1

to 65535

Factory

Setting: 4

For Position

Control Only

Cn-25

RATA

Electronic Gear Ratio

(Denominator)

Unit:

None

Setting

Range: 1

to 65535

Factory

Setting: 1

For Position

Control Only

These user constants are for position control only.

Set the electronic gear ratio according to machine
specifications.

Electronic gear ratio

B

A

= Cn-24

Cn-25

B = [(Number of encoder pulses) x 4] x [Motor shaft rotating speed]
A = [Load travel distance per revolution of load shaft (Reference unit)] x [Load shaft

rotating speed]

Note that the user constant settings must meet the following condition:

0.01 ≤

B

A

≤ 100