Yaskawa DR2 Sigma Servo User Manual

Page 142

Advertising
background image

3.7 Forming a Protective Sequence

129

2) Contact Output Signal ALM+, ALM-

Output ALM+ 1CN-31

Servo Alarm Output

For Speed Torque

Control and

Position Control

Output ALM- 1CN-32

Signal Ground for Servo

Alarm Output

For Speed Torque

Control and

Position Control

Signal ALM+ is output when the Servopack de-
tects an alarm.

Form an external circuit so that this alarm output
(ALM) turns the Servopack main power OFF.

ON
status:

Circuit between 1CN-31 and 1CN-32 is closed.
1CN-31 is at low level.

Normal state

OFF
status:

Circuit between 1CN-31 and 1CN-32 is open.
1CN-31 is at high level.

Alarm state

Alarm codes ALO1, ALO2, and ALO3 are output to indicate each alarm type.

3) Contact Output Signals ALO1, ALO2, and ALO3

Output ALO1 1CN-37

Alarm Code Output

For Speed/Torque

Control and

Position Control

Output ALO2 1CN-38

Alarm Code Output

For Speed/Torque

Control and

Position Control

Output ALO3 1CN-39

Alarm Code Output

For Speed/Torque

Control and

Position Control

Output SG

1CN-2

Signal Ground for Alarm Code

Output

For Speed/Torque

Control and

Position Control

These signals output an alarm code to indicate the type of an alarm detected by the Ser-
vopack.

Use these signals to display alarm codes at the host controller.

3

Servopack

Alarm

detection

ALM+ output

Turns the power

OFF

Advertising
This manual is related to the following products: