USING THE DIGITAL OPERATOR

4.2.4 Reference Offset Automatic Adjustment cont.

196

3) Using the Reference Offset Automatic Adjustment Mode

Follow the procedure below to automatically adjust the reference offset.

1) Follow the procedure below to set the mo-

tor into operating mode.

(1) Input the (intended) 0 V reference voltage

from the host controller or external circuit.

(2) Then, turn ON the servo ON (1CN-40,

S-ON) signal.

2) Press

DSPL

SET

to select the user constant

setting mode.

3) Select the user constant number Cn-00.

(User constant Cn-00 is selected when the
power is turned ON.)

Press the

and

keys to select the

digit.

Press the

and

keys to change the

value.

4) Press

DATA

ENTER

to display the current data for

the user constant Cn-00.

5) Press the

and

keys to change the

data to 01.

6) Press

DSPL

SET

to automatically adjust the

reference offset. The motor rotation stops.

7) Press

DATA

ENTER

to return to the setting mode

display. This ends reference offset auto-
matic adjustment.

4

Host

Controller

0 V Speed

Reference

or Torque

Reference

Servo ON

Motor

Slow Rotation

Servopack

Setting Mode

Select Cn-00.

The selected digit

blinks.

User Constant Number

Data

Set to 00-01.

keys to change the

value.

Press the

Slow

Rotation

Motor Stops

Setting Mode Display