SERVO SELECTION AND DATA SHEETS

5.4.1 Servomotor Dimensional Drawings cont.

276

4) The quoted allowable radial load is the value at a position 20 mm (0.79in.) from the motor

mounting surface.

5) The electromagnetic brake is only to hold the load in position and cannot be used to stop

the motor.

6) Conforms to IP55 protective structure (except connector and output shaft faces).

• 200 W (0.27HP), 300W (0.40 HP), 400 W (0.53HP)

Encoder Lead

Encoder Plug

Motor Plug

Sealant

Incremental Encoder

2048 P/R

Holding Brake (deenergization

operation)
Voltage: 90 VDC
Brake holding torque = motor

rated torque

Cross-section Y-Y

Hex. nut 14

(0.55)

Motor Lead

4-∅0.7

(4-∅0.28)

MTG Holes

Screw

Shaft end screw hole

(SGMP-jjA(B)316B,