3.2.9 Using Torque Restriction by Analog Voltage Reference

98

• This function cannot be used with the function for torque restriction by analog voltage

reference, described in 3.2.9 Using Torque Restriction by Analog Voltage Reference.

• For user constants and control modes, refer to Appendix D List of User Constants.

3) Setting a Torque Feed-forward Value in User Constant Cn-13

The factory setting is Cn-13 = 30. If, for example, the torque feed-forward value is 3 V,
torque is restricted to 100% (rated torque).

Cn-13

TCRFGN

Torque Reference

Gain

Unit: 0.1

V/Rated

Torque

Setting

Range:

10 to 100

Factory

Setting:

30

For Speed/Torque

Control Only

3.2.9 Using Torque Restriction by Analog Voltage Reference

For speed control only.

1) Outline

This function restricts torque by assigning the T-REF terminal (1CN-9, 1CN-10) a torque
limit value in terms of analog voltage. Since torque reference input terminal T-REF is
used as an input terminal, this function cannot be used for torque control.

Torque limit value

Speed reference

Speed loop

gain (Cn-04)

Integration

(Cn-05)

Torque limit value

Torque

reference

Speed feedback

Schematic Block Diagram for Torque Restriction by Analog Voltage Reference

3