6.2 Troubleshooting

393

D

Display and Outputs

Digital Operator

Di l

d

Alarm Output

g

p

Display and

Alarm Name

Alarm Code Output

Alarm Output

Alarm Name

ALO1

ALO2

ALO3

p

A.04

User constant

setting error

OFF

OFF

OFF

OFF

OFF: Output transistor is OFF
ON: Output transistor is ON

Status When Alarm Occurred

At control power ON

A

,

B

Cause

Remedy

A

An out-of-range user constant was

previously set or loaded.

Reset all user constants in range.

Otherwise, re-load correct user constants.

B

Circuit board (1PWB) defective

Replace Servopack.

D

Display and Outputs

Digital Operator

Di l

d

Alarm Output

g

p

Display and

Alarm Name

Alarm Code Output

Alarm Output

Alarm Name

ALO1

ALO2

ALO3

p

A.10

Overcurrent

ON

OFF

OFF

OFF

OFF: Output transistor is OFF
ON: Output transistor is ON

Note

Alarm A10 is reset when the power is turned OFF and back ON. It is not reset by the normal
alarm reset.

Status When Alarm Occurred

During servomotor

operation

When servo ON (S-ON)

signal turned ON

A

,

B

,

C

, D, E

D,

E

At main circuit power

ON

D

6